Power & Generator Solutions

Advanced generator controllers with protection, auto start features, and remote monitoring.

AUTOMATIC MAINS FAILURE ? ENHANCED AUTO/AMF SURF V1.3a
AUTOMATIC MAINS FAILURE ? ENHANCED AUTO/AMF SURF V1.3a
AUTOMATIC MAINS FAILURE- LITE VERSION AUTO/ AMF SURF LT V1.0
AUTOMATIC MAINS FAILURE- LITE VERSION AUTO/ AMF SURF LT V1.0
Automatic mains failure or Auto Start controller Simultaneous display of AC voltage, currents, frequency, hour counter, oil pressure, engine temperature and battery voltage Display of power in KW and energy in KWh of both engine and Utility Display of fuel consumption rate (L/h), total fuel consumption, tank percentage and RPM Display of power factor of each line Display of Software version, the date and time, the continuous hour counter and the utility hour counter CAN bus J1939 CAN bus with BAMVI_CAN that can read DC voltage up to 275Vdc and DC current up to +-300Amps (Optional) USB interface Interfaces RS485 Modbus/CAN On-site firmware upgrade
AUTOMATIC TRANSFER SWITCH CONTROLLER OMEGA ATS V1.2 / STD - E - M - EM
AUTOMATIC TRANSFER SWITCH CONTROLLER OMEGA ATS V1.2 / STD - E - M - EM
For 1 utility (optional) & 2 generators of the same rating: Alternate function to keep running hours of the gensets equal For 1 utility (optional) & up to 3 generators of different rating: Automatic switching between the gensets based on the load Isolated measurement of the voltages and frequency on all sources Current measurement on the load side Graphical LCD display 4GB Micro SD card for event and data logging Ethernet interface USB interface Serial RS485 Modbus protocol Internet communication On-site firmware upgrade
AUTO START WITH VOLTAGE AND FREQUENCY SMART/TURBO
AUTO START WITH VOLTAGE AND FREQUENCY SMART/TURBO
Voltage display & protection Battery voltage display & protection Frequency display & protection Run hour counter Run hours since the last oil change
AUTO START WITH VOLTAGE, FREQ AND CURRENT SMART/GT
AUTO START WITH VOLTAGE, FREQ AND CURRENT SMART/GT
Voltage display & protection Battery voltage display & protection Frequency display & protection Current display & protection Oil Pressure display & protection Temperature display & protection Run hour counter Run hours since the last oil change On-site firmware upgrade
12V/5A Battery charger (Input: 90-240VAC) MAXIBAT
12V/5A Battery charger (Input: 90-240VAC) MAXIBAT
Intelligent 12v/5A battery charger LCD display Display of the battery voltage, current and charge status Charging operating modes: trickle, boost, float, and full
12V/3A Battery charger (Input: 48VDC) CHARGER-48i
12V/3A Battery charger (Input: 48VDC) CHARGER-48i
12V/3A battery charger from 48V battery source Charging operating modes: boost and float
DIESEL KEY START WITH LOW COOLANT SMD DKSTLS
DIESEL KEY START WITH LOW COOLANT SMD DKSTLS
DIESEL KEY START BOARD SMD DKSTS
DIESEL KEY START BOARD SMD DKSTS
DIESEL REMOTE START BOARD DRST
DIESEL REMOTE START BOARD DRST
Presettable response delay Presettable cooling delay Presettable starter time Three to four starting attempts Universal supply voltage Alarm output
SMART KWHMETER WITH RS485 (MODBUS) RM-MB-20A
SMART KWHMETER WITH RS485 (MODBUS) RM-MB-20A
LCD display for energy in KWh and AC voltage LCD display for frequency and current LCD display for subscription status Over current monitoring Power cut relay
DIGITAL THREE PHASE VOLTAGE RELAY PH3D V13 / STD_1C - STD_2C
DIGITAL THREE PHASE VOLTAGE RELAY PH3D V13 / STD_1C - STD_2C
Display of all voltages Over/Under voltage Phase failure Wrong phase sequence Asymmetry
DIGITAL SINGLE PHASE VOLTAGE RELAY SPHD V1.3
DIGITAL SINGLE PHASE VOLTAGE RELAY SPHD V1.3
Voltage display Over/Under voltage
PHASE SEQUENCE / FAILURE RELAY PHF V2.1
PHASE SEQUENCE / FAILURE RELAY PHF V2.1
Phase failure detection Wrong phase sequence detection
DIGITAL FREQUENCY RELAY FRWD V1.3
DIGITAL FREQUENCY RELAY FRWD V1.3
Frequency display Over/Under frequency
DIGITAL CURRENT RELAY OCR1D V1.0
DIGITAL CURRENT RELAY OCR1D V1.0
Current display Over/Under current Submersible water pump application
DIGITAL BATTERY VOTLAGE MONITOR BAMVI.STD
DIGITAL BATTERY VOTLAGE MONITOR BAMVI.STD
DC voltage (Up to 330 V) monitoring Auxiliary supply control
DIGITAL BATTERY VOLTAGE AND CURRENT MONITOR BAMVI.C
DIGITAL BATTERY VOLTAGE AND CURRENT MONITOR BAMVI.C
DC voltage (Up to 330 V) & DC current (Up to +/- 300A) monitoring Auxiliary supply control
DIGITAL BATTERY VOLTAGE & CURRENT MONITOR W CAN BUS BAMVI/CAN
DIGITAL BATTERY VOLTAGE & CURRENT MONITOR W CAN BUS BAMVI/CAN
CAN Bus communication DC voltage (Up to 330 V) & DC current (Up to +/- 300A) monitoring Auxiliary supply control
PLC CURRENT INTERFACE PLC CI
PLC CURRENT INTERFACE PLC CI
0-5A Current transducer with 0-10VDC output True root mean square (rms) current measurement Interfaces with 5A current transformer Case conforms to DIN 43 880 of the British Standard