Power & Generator Solutions

Advanced generator controllers with protection, auto start features, and remote monitoring.

AUTOMATIC MAINS FAILURE ? ENHANCED AUTO/AMF SURF V1.3a
AUTOMATIC MAINS FAILURE ? ENHANCED AUTO/AMF SURF V1.3a
Automatic mains failure or Auto Start controller. 3.5 - TFT screen. Display of AC voltage, currents, frequency, hour counter, oil pressure, engine temperature, oil temperature, and battery voltage. Display of power in KW and energy in KWh of both engine and Utility. Display of fuel consumption rate (L/h), total fuel consumption, tank percentage, and RPM. Display of power factor of each line. 4/8GB Micro SD card for event and data logging. CAN bus J1939 enabled. Ethernet interface. SNMP Server protocol (Get/Set using Versions v1/v2c, send traps with compliance to RFC1215). SNTP Client (Automatically synchronize time with a modifiable SNTP server). HTTP Server protocol (Retrieve logs/Download Firmware via Ethernet). MQTT protocol USB interface.Serial RS232S interface. Serial RS485.Modbus protocol. Parameters can be edited and updated from any remote interface at any time even when the engine is running. Menu is accessible from the front panel as well as USB, Ethernet. Supports communication and SMS via GSM modem. Supports 4-pole systems (Utility and Genset AC inputs are isolated). Accepts Genset frequencies of up to 500Hz. Supports three current transformer inputs for 50Hz current transformers or up to 500Hz using current transducers (optional and sold separately).
AUTOMATIC MAINS FAILURE- LITE VERSION AUTO/ AMF SURF LT V1.0
AUTOMATIC MAINS FAILURE- LITE VERSION AUTO/ AMF SURF LT V1.0
Automatic mains failure or Auto Start controller Display of AC voltage, currents, frequency, hour counter, oil pressure, engine temperature and battery voltage Display of power in KW and energy in KWh of both engine and Utility Display of fuel consumption rate (L/h), total fuel consumption, tank percentage and RPM Display of power factor of each line USB interface RS485 modbus or CAN J1939 On-site firmware upgrade
AUTOMATIC TRANSFER SWITCH CONTROLLER OMEGA ATS V1.2 / STD - E - M - EM
AUTOMATIC TRANSFER SWITCH CONTROLLER OMEGA ATS V1.2 / STD - E - M - EM
For 1 utility & 2 generators of the same rating: Alternate function to keep running hours of the gensets equal For 1 utility & 2 generators of different rating: Switching between gensets based on the load For up to 3 generators of different rating: Automatic switching between the gensets based on the load Isolated measurement of the voltages on all sources Current measurement on the load side Graphical LCD display 4GB Micro SD card for event and data logging Ethernet interface USB interface Serial RS485 Modbus protocol Internet communication On-site firmware upgrade
AUTO START WITH VOLTAGE AND FREQUENCY SMART/TURBO
AUTO START WITH VOLTAGE AND FREQUENCY SMART/TURBO
Auto Start Display of AC voltage, frequency, battery voltage, run hour or run hours since the last oil change Over/Under voltage, frequency, battery voltage protection
AUTO START WITH VOLTAGE, FREQ AND CURRENT SMART/GT
AUTO START WITH VOLTAGE, FREQ AND CURRENT SMART/GT
Display of AC voltage frequency, current, oil pressure, temperature, run hour counter or run hours since the last oil change Over/Under voltage, frequency, battery voltage protection Over current protection
12V/5A Battery charger (Input: 90-240VAC) MAXIBAT
12V/5A Battery charger (Input: 90-240VAC) MAXIBAT
Intelligent 12v/5A battery charger Display of the battery voltage, current and charge status Charging operating modes: trickle, boost, float, and full
12V/3A Battery charger (Input: 48VDC) CHARGER-48i
12V/3A Battery charger (Input: 48VDC) CHARGER-48i
12V/3A battery charger from 48V source Charging operating modes: boost and float
DIESEL KEY START WITH LOW COOLANT SMD DKSTLS
DIESEL KEY START WITH LOW COOLANT SMD DKSTLS
DIESEL KEY START BOARD SMD DKSTS
DIESEL KEY START BOARD SMD DKSTS
DIESEL REMOTE START BOARD DRST
DIESEL REMOTE START BOARD DRST
DIESEL REMOTE START BOARD Presettable response delay Presettable cooling delay Presettable starter time Three to four starting attempts Universal supply voltage Alarm output
SMART KWHMETER WITH RS485 (MODBUS) RM-MB-20A
SMART KWHMETER WITH RS485 (MODBUS) RM-MB-20A
LCD display for energy in KWh and AC voltage Frequency and current Subscription status Over current monitoring Power cut relay
DIGITAL THREE PHASE VOLTAGE RELAY PH3D V13 / STD_1C - STD_2C
DIGITAL THREE PHASE VOLTAGE RELAY PH3D V13 / STD_1C - STD_2C
Display of all voltages Over/Under voltage Phase failure Wrong phase sequence Asymmetry
DIGITAL SINGLE PHASE VOLTAGE RELAY SPHD V1.3
DIGITAL SINGLE PHASE VOLTAGE RELAY SPHD V1.3
Voltage display Over/Under voltage
PHASE SEQUENCE / FAILURE RELAY PHF V2.1
PHASE SEQUENCE / FAILURE RELAY PHF V2.1
Phase failure detection Wrong phase sequence detection
DIGITAL FREQUENCY RELAY FRWD V1.3
DIGITAL FREQUENCY RELAY FRWD V1.3
Frequency display Over/Under frequency
DIGITAL CURRENT RELAY OCR1D V1.0
DIGITAL CURRENT RELAY OCR1D V1.0
Current display Over/Under current Submersible water pump protection application
DIGITAL BATTERY VOTLAGE MONITOR BAMVI.STD
DIGITAL BATTERY VOTLAGE MONITOR BAMVI.STD
DC voltage (Up to 330 V) monitoring Auxiliary supply control
DIGITAL BATTERY VOLTAGE AND CURRENT MONITOR BAMVI.C
DIGITAL BATTERY VOLTAGE AND CURRENT MONITOR BAMVI.C
DC voltage (Up to 330 V) & DC current (Up to +/- 300A) monitoring Auxiliary supply control
DIGITAL BATTERY VOLTAGE & CURRENT MONITOR W CAN BUS BAMVI/CAN
DIGITAL BATTERY VOLTAGE & CURRENT MONITOR W CAN BUS BAMVI/CAN
CAN Bus communication DC voltage (Up to 330 V) & DC current (Up to +/- 300A) monitoring Auxiliary supply control
PLC CURRENT INTERFACE PLC CI
PLC CURRENT INTERFACE PLC CI
0-5A Current transducer with 0-10VDC output True root mean square (rms) current measurement Interfaces with 5A current transformer Case conforms to DIN 43 880 of the British Standard